SS 16.4 Installation and Operation Manual
INSTALLATION
Serial Control:
The unit is controlled in either Menu or Burst mode. It can run at the following
data rates:
• 2400
• 9600 Default
• 19,200
• 38,400
Serial communications is either multi-drop RS-232 or RS-485, jumper selectable.
Commands may be entered either via a menu (menu mode) or a short form code
(burst mode). All commands and responses use normal ASCII characters, facilitat-
ing scripting. A burst mode command starts with an asterisk (“*”) followed by the
device (ID) address as a single decimal digit. A burst mode command must be
entered within 5 seconds or it will time out. The command to enter menu mode
starts with an asterisk (“*”) followed by the device (ID) address as a single decimal
digit and then MM. The menu mode displays certain parameters, and allows the
setting of these parameters. In both cases, device (ID) address (0-3) is specified
with the on-board dipswitches.
Type *0MM, follow the prompts on the pop-up menu.
Menu Mode:
The command to enter menu mode starts with an asterisk (“*”) followed by the
device (ID) address as a single decimal digit, then the MM command. NOTE:
Commands you type will NOT be seen, unless you turn “Echo On” in
HyperTerminal. The menu mode displays advanced configuration parameters.
Unit ID, Baud rate and other configurations are set via the on-board dipswitches
(SW24) at the rear of the unit.
Broadcast Tools® SS 16.4, v1.xx - Setup Menu
1 - Set PIP Minimum (0 - 2.55 sec) - Now: 1.00
2 - Set Remote Mode Open Collector Mode - Now: "Follow"
3 - Set Silence Sense Acquire Delay (sec) - Now: 10
4 - Set Silence Sense Restore Delay (sec) - Now: 10
A - Save Current Audio State for Power Up
C - Show Current Configuration
F - Set Factory Defaults
Enter Selection, or Q to quit.