5.8.7 Set Mode (Operating Mode) Task
The Set Mode (Set Operating Mode) task is used to set the current operating mode of the system.
There are 4 modes from which to choose:
Emergency
Live
Automation
Satellite
The operating mode affects how the system reacts to things like log directives, input relays and a
number of other events that occur. This task is most often used when transitioning to and from satellite
programming.
Set Mode Properties
Items with a check mark in the REQ column require user entry, while unchecked items have default
values which can optionally be changed.
Property
REQ
Description
Task Name
The user-friendly name of the task. See Common Properties for
more information.
Operating Type
Select the appropriate mode item from the dropdown list. The
default is "Automation".